17
GTS 200
Ignition
Adjust Ignition Armature Air Gap
1. Rotate flywheel until magnet is under armature
laminations.
2. Place thickness gauge, Table No. 1, Page 17, between
magnet and armature laminations, Fig. 18.
1
2
3
4
5
Fig. 18 – Adjusting Armature Air Gap
1.
Magnet
2.
Turn magnet away from
armature
3.
Armature down; gauge
stock in place
4.
Turn
5.
Roll out gauge
3. See Table No. 1, Page 17 for armature air gap. Loosen
mounting screw so magnet will pull armature down against
thickness gauge.
4. Torque both mounting screws to 25 in. lbs.
(3.0Nm) Rotate
flywheel to remove thickness gauge.
5. Install outer blower housing and screws and torque screws
to 85 in. lbs., (10.0Nm)
,
Fig. 19.
1
1
Fig. 19 – Installing Outer Blower Housing
1.
Torque screws to 85 in. lbs.
Specifications
Table No. 1
Armature Air Gap
Flywheel Puller
Briggs & Stratton Tool #
Flywheel Holder
Briggs & Stratton Tool #
Flywheel Nut Torque
.006” – .012”
(0.15 – 0.30mm)
19069
19372
60 ft. lbs.
(81.0Nm)