SOLENOID VALVE / PUMP WIRING
Step 4
1.
Plug the Tempus Air MV as shown below. Use 9V solenoid valves only for a master valve and a relay for a pump
use.
+S- C P 1
+S- C P 1
CHOICE AND SENSOR SETUP
Step 5
Warning, by default there are no sensor configured.
The Tempus Air MV has a + S - sensor input on which you can connect a rain sensor or a flow meter/water meter
or pressure switch after cutting the blue wire. Once the sensor is connected, it is necessary to configure it in the
application.
1. Using the MyToroTempus mobile app, connect to your Tempus Air MV via Bluetooth.
2. Click on Add Sensor.
3. Select your sensor type and follow the instructions given by the application.
Jumper wire
Valve common wire
Vanne 1
Jumper wire
Jumper wire
Jumper wire
Valve common wire
Valve common wire
Valve common wire
Rain sensor
Pressure switch
Water meter
Vanne 1
Vanne 1
Vanne 1
+S- C P 1
+S- C P 1
+S- C P 1
Rain sensor
Pressure switch (AON = All or Nothing)
Water meter
Connect your
+ S -
input to a water meter equipped with
a flow sensor as shown above. Use dry contact flow
sensors or equivalent. For polarized flow sensors, when
wiring,observe the polarization :
Red wire -> + Black wire - > -
Valve 1
Valve 1
Valve 1
Valve 1