g034324
Figure 40
1.
Increase the desired
distance.
2.
Decrease the desired
distance.
Performing the Speed and Distance Test
1.
Ensure that the boom sections are off and press
button 2 to begin calibration.
Note:
As you drive the machine, and the speed
calibration progresses, the InfoCenter displays
distance until it reaches the set amount.
Important:
Do not shut off the machine after
the speed calibration completes.
2.
Start the engine and release the parking brake.
3.
Beginning with the center of the front tire at the
“0” mark, drive the vehicle at approximately 5 to
8 kph (3 to 5 mph) to the other mark, and stop
with the center of the front tire on the mark.
4.
Press button 2 to confirm the distance traveled.
5.
If the calibration is successful, a Calibration
Successful screen appears; press button 5 to
exit.
6.
If the calibration is not successful, a Calibration
Failed screen appears with the reasoning behind
why the calibration failed; press button 5 to exit
and restart the calibration.
7.
Set the parking brake, shut off the engine, and
remove the key from the key switch.
Manual Calibration Entry
This screen allows you to view and edit the speed
calibration number.
Service Screen
To access the Service screen, press button 2 on the
Main Menu screen (
) until you reach Service,
and press button 4 to select Service.
g035343
Figure 41
From the Service screen, select the Hours screen to
view the overall hours of machine, the pump operation
hours, and when the next service is due (
g034304
Figure 42
To reset the Hours screen, press and hold button 3
(
).
38