Start and High Temp. Relays
(Reelmaster 216-D only)
(Fig. 13, 14, 15)
To test the relay, disconnect the relay wire connector
and install a continuity tester between the relay termi
nals (terminals 30 and 87). The relay should make and
break continuity at terminals 30 and 87 as 12 V.D.C. is
connected and disconnected to terminal 85 with termi
nal 86 connected to ground.
1
Figure 13
1. Start relay (Item 39)
1
Figure 14
1. High temp. relay (Item 34)
Figure 15
Testing
Page 6 - 24
Reelmaster
®
216/216-D