g376340
Figure 103
1.
Return filter
2.
Filter head
3.
Remove the filter.
4.
Wipe clean the filter mounting area of the filter
head.
5.
Apply a thin coat of the specified hydraulic fluid
to the gasket of the new return filter.
6.
Thread the filter onto the filter head by hand until
the gasket contacts the mounting surface, then
rotate the filter an additional 1/2 turn.
Changing the Charge Filter
1.
Prepare the machine for maintenance; refer to
Preparing for Maintenance (page 40)
.
2.
Tilt the seat; refer to
Tilting the Seat (page 41)
.
3.
At the left side of the machine, align a drain pan
under the charge filter (
).
g376339
Figure 104
1.
Filter head
2.
Charge filter
4.
Remove the filter.
5.
Wipe clean the filter mounting area of the filter
head.
6.
Apply a thin coat of the specified hydraulic fluid
to the gasket of the new charge filter.
7.
Thread the filter onto the filter head by hand until
the gasket contacts the mounting surface, then
rotate the filter an additional 1/2 turn.
8.
Lower and latch the seat; refer to
.
Checking for Leaks
1.
Start the engine and run it for 2 minutes to purge
air from the hydraulic system.
2.
Shut off the engine, remove the key, and check
for leaks at the return and charge filters.
Note:
Repair all hydraulic leaks.
Hydraulic Fluid Capacity
34 L (9 US gallons); refer to
Specifications (page 58)
Changing the Hydraulic
Fluid
Service Interval:
Every 2,000 hours—
If you
are using the recommended
hydraulic fluid,
change the
hydraulic fluid.
Every 800 hours—
If you are not using the
recommended hydraulic fluid or have ever
60
Summary of Contents for Reelmaster 5610
Page 68: ......