Rev. B
Reelmaster 6500–D/6700–D
Page 4 – 38
Hydraulic System
TEST NO. 9: Reel Drive Motor Efficiency
(Using Tester with Pressure Gauges and Flow Meter)
Install tester in series
between fitting and hose at
motor outlet.
NOTE: Outlet is rear hose.
M5A
D4
M4A
M4
M1
M5
R3
R3
R3
R3
R3
R3
Front Valve Block
Disconnect case drain
hose (small diameter
hose) at bulkhead fitting
on frame.
High Pressure
Low Pressure
Flow
Outlet hose
Case drain hose
Case Drain
Figure 19