Battery Charging Table
Charger Setting
Charging Time
4 to 6 amperes
30 minutes
25 to 30 amperes
10 to 15 minutes
5.
When the battery is fully charged, unplug the charger
from the electrical source, then disconnect the charger
leads from the battery posts (Figure 59).
Replacing a Fuse
1.
Remove the right side panel; refer to Removing the
Side Panels (page 36).
2.
Rotate the battery-disconnect switch counterclockwise
to the Off position (Figure 60).
Figure 60
1.
Battery-disconnect switch
in the On position
2.
Battery-disconnect switch
in the Off position
3.
Replace the open (blown) fuse in the fuse block with a
new fuse that has an equivalent amperage value (Figure
61).
Figure 61
1.
Fuse block
4.
Rotate the battery-disconnect switch clockwise to the
On position (Figure 18).
5.
Install the right side panel; refer to Installing the Side
Panels (page 37).
48
Summary of Contents for RT600
Page 71: ...Notes 71...