7-20
Digital Edition - TIMECUTTER® HD Service Manual
April 2017
HYDROSTATIC DRIVE SYSTEM
Hydrostatic Drive Transmission (Cont.)
Installation (Right side shown) (Cont.)
14. Add hydraulic oil to the proper level using the vent plugs (Figure 21).
15. Follow the purging procedure to remove all air from the system,
see “Purging Procedure,” chapter 7, page
16. Adjust the neutral setting if necessary,
see “Hydrostatic Drive Belt Installation,” chapter 7, page 7-11.
17. Lower the unit and verify proper function.
18. Adjust the tracking if necessary,
see “Tracking Adjustment,” chapter 7, page 7-6.
19. Connect the battery terminals and verify proper function.
Vent Plug
Figure 21