G014973
1
2
3
g014973
Figure 54
1.
Blade (in position for measuring)
2.
Level surface
3.
Measured distance between blade and the surface (A)
4.
Rotate the same blade 180 degrees so that
the opposing cutting edge is now in the same
position (
G014974
1
2
3
g014974
Figure 55
1.
Blade (side previously measured)
2.
Measurement (position used previously)
3.
Opposing side of blade being moved into measurement
position
5.
Measure from the tip of the blade to the flat
surface (
).
Note:
The variance should be no more than
3 mm (1/8 inch).
G014973
1
2
3
g014973
Figure 56
1.
Opposite blade edge (in position for measuring)
2.
Level surface
3.
Second measured distance between blade and surface (B)
A.
If the difference between A and B is greater
than 3 mm (1/8 inch), replace the blade with
a new blade; refer to
(page 45)
and
Installing the Blades (page
.
Note:
If a bent blade is replaced with a
new blade, and the dimension obtained
continues to exceed 3 mm (1/8 inch), the
blade spindle could be bent. Contact an
Authorized Toro Dealer for service.
B.
If the variance is within constraints, move to
the next blade.
6.
Repeat this procedure on each blade.
44