Servicing the Fuses
The electrical system is protected by fuses. It requires
no maintenance; however, if a fuse blows, check the
component/circuit for a malfunction or short.
Fuse:
•
Main F1-30 amp, blade-type
•
Charge Circuit F2-25 amp, blade-type
1.
Remove the screws securing the control panel to the
machine. Retain all fasteners
2.
Lift the control pane up to access the main wiring
harness and fuse block (
).
3.
To replace a fuse, pull out on the fuse to remove it
(
).
30
25
30
25
G014921
2
1
Figure 39
1.
Main-30 amp
2.
Charge circuit-25 amp
4.
Return the control panel to its original position. Use
the screws removed previously to secure the panel to
the machine.
Drive System
Maintenance
Checking the Tire Pressure
Service Interval:
Every 25 hours—Check tire pressure.
Maintain the air pressure in the front and rear tires as
specified. Uneven tire pressure can cause uneven cut. Check
the pressure at the valve stem (
). Check the tires
when they are cold to get the most accurate pressure reading.
Refer to the maximum pressure suggested by the tire
manufacturer on the sidewall of the caster wheel tires.
Inflate the rear drive wheel tires to 90 kPa (13 psi).
Figure 40
1.
Valve stem
Releasing the Electric Brake
The electric brake releases by manually rotating the link arms
forward. Once the electric brake is energized the brake will
reset.
To release the brake:
1.
Turn the ignition key to the Off position or disconnect
the battery.
2.
Locate the shafts where the brake-link arms are
connected on both sides of the electric brake (
3.
Rotate the shafts forward to release the brakes.