g336413
Figure 128
TVS Diode Testing
If the main fuse blows each time the PTO clutch is engaged, check the TVS
diode.
1. Disconnect the TVS diode from the harness.
2. Connect each lead of the meter to each terminal of the TVS diode.
3. If the TVS diode is internally shorted, replace the TVS diode.
4. If the TVS diode is not internally shorted, check the wiring and the clutch.