81
Deutsch
English
Display
Cause
What to do
E70
Battery outside temperature
range during charging
System can be operated when battery is inside temperature
range again. Disconnect the charger for better cooling.
Switch battery OFF and ON.
E71
Battery outside temperature
range during discharging
System can be operated when battery is inside temperature
range again. Stop or reduce current drawn from battery for
better cooling. Switch battery OFF and ON.
E72
Battery FETs outside
temperature range
System can be operated when battery is inside temperature
range again. Switch battery OFF and ON.
E73
Overcurrent during discharging
Remove cause for overcurrent. Switch battery OFF and ON.
E74
Overcurrent during charging
Disconnect charger. Use only Torqeedo charger. Switch
battery OFF and ON.
E75
Pyro-fuse released
Contact Torqeedo service.
E76
Voltage too low
Charge battery.
E77
Voltage too high during
charging
Disconnect charger. Use only Torqeedo charger. Switch
battery OFF and ON.
E78
Battery over-charged
Disconnect charger. Use only Torqeedo charger. Switch
battery OFF and ON.
E79
Electronic battery malfunction
Contact Torqeedo Service.
E80
Deep discharge
Contact Torqeedo Service.
E81
Water-sensor deployed
Ensure that the battery is dry/in a dry place. If needed clean
battery housing incl.its water detector. Switch battery OFF
and ON.
E82
Disbalancing among different
batteries
Charge all batteries individually to full.
E83
Software version error
Batteries with different software versions were connected.
Contact Torqeedo Service.
E84
Number of batteries does not
match enumeration process
results
Check battery connections. The expected number of
batteries is shown in the display under the error code. Check
function of individual batteries. Potentially re-establish
communication between outboard and battery as described
under 5.3.1.1.
E85
Disbalancing within one battery
During the next charging process: do not disconnect charger
from the battery. Leave charger connected to the battery
after the charging process is completed for at least 24 hours.
Battery error codes (only in combination with Power 26-104)
Display
Cause
What to do
E32
Tiller/Remote throttle
Check the plug-in connections. Check the cable.
E33
General communication
error
Check the plug-in connections and cables. Switch the
motor off and on again.
E43
Battery empty
Charge battery. Motor can potentially be used again slowly
from the stop position.
Other error
codes
Faulty
Contact Torqeedo Service and notify them of the error
code.
No function of
display
No power / faulty
Check power connection to motor incl. on/off switch. If
power connection is flawless, contact Torqeedo Service.