background image

Mechanical Specifications

Model Number

RM 20 BAL RK

RM 20 BAL CB

RM 20 BAL CS

RM 20 RK

RM 20 CB

RM 20 CS

Input

Connector

(Rear Panel)

IEC 20A

Inlet

IEC 20A

Inlet

Line Cord

(included)

N6/15, 14AWG

C19, 15A/250V

N5/20, 12AWG

C19, 20A/125V

Suggested

Wall

Receptacle

NEMA 6-15R

15A - 250V

NEMA 5-20R

20A - 125V

Output

Connector

(Rear Panel)

Qty 5 (10 outlets)

Medical-grade

duplex 20A

Qty 5 (10 outlets)

Medical-grade

duplex 20A

Weight

40.5kg

39.5kg

43.2kg

42.2kg

Size mm

(w x d x h)

483 x 426 x 159

432 x 402 x 162

483 x 426 x 159

432 x 402 x 162

Torus PIUs are high-power products.

The outlets they are plugged into

should be sufficient to provide the

current to operate them without

tripping circuit breakers within your

junction panel.

D e d i c a t e d

c i r c u i t s

a r e

recommended.

Balanced

input

products,

240VAC,

require

dual

120V phases (2 pole, 3-wire). Wall

outlets for 240VAC are rated at 250V

and

will

likely

require

special

installation. Dedicated outlets, or

any household or facility wiring

should be installed by a licenced

electrician to local codes.

Pictured

below

are

suggested

receptacle types for installation.

Rear Panel Layout

Wall Receptacles

NEMA 6-15R

for Balanced 20A unit

NEMA 5-20R

for Single 20A unit

Balanced 20A, Model Numbers RM 20 BAL RK,

RM 20 BAL CB and RM 20 BAL CS

Product Label

Power Inlet

Accessory
Ground Stud

20A Medical-Grade Outlet

Single 20A, Model Numbers RM 20 RK,

RM 20 CB and RM 20 CS

Line Cords

Standard 15A 240/208V

Used on:

Equipment end:
Plug:

Cord:
Length:

Model Numbers RM 20 BAL RK,

RM 20 BAL CB and RM 20 BAL CS

IEC C19

6-15P, Straight Blade, 2 pole,

3-wire grounding, 15A 250V

3 x 14AWG

2.5 m

Standard 20A 120V

Used on:

Equipment end:
Plug:

Cord:
Length:

Model Numbers RM 20 RK,

RM 20 CB and RM 20 CS

IEC C19

5-20P, Straight Blade, 2 pole,

3-wire grounding, 20A 125V

3 x 12AWG

2.5 m

www.TorusPower.com

Owner’s Manual

Audio / Video Power Isolation Units

Rack Mount / Consumer

03/12

Power Conditioners

Rubber
Mounting Feet
(may be
removed if rack
mounting)

Height includes rubber mounting feet.

REV.03/01/2012