7-4. AUTO Operation
(MODE of the remote control : AUTO)
(1) One of the 2 modes, Cooling or Dry is selected
according to room temperature at which operation
is to start, as shown in Fig. 7-4-1. The Fan mode
will continue until room temperature reaches a
level at which another mode is selected.
7-4-1. Temporary Auto
When the TEMPORARY button is pushed, the set
temperature is fixed at 24°C and controlled in accor-
dance with the chart shown in Fig. 7-4-1.
Fig. 7-4-1
Cooling mode
Cooling mode
Dry mode
+4
+1
(The same cooling mode as the room temperature control is set at set temp. –1˚C)
The Louver moved downward.
(The same cooling mode as the room temperature control is set at set temp. –1˚C)
(The same dry operation as the room temperature control is set at set temp. –1˚C)
(Room temp. – Set temp.)