TOSHIBA
6 - 1
6.0
UPS Control Interface
6.1
Remote Contact and IBM AS/400
The AS/400 interface is a standard feature and is available as dry switch contacts
through a DB9 male connector located on the back side of the UPS (see Section 9.1,
9.2 or 9.3). The AS/400 interface uses standard pins numbered 5 through 9. Pins
numbered 1 through 4 are also assigned for usage in addition to AS/400. The following
schematic shows the contact state and pin assignment for each signal output along
with the associated DB9 connector pinout.
1
2
3
4
5
6
7
8
9
DB9 Male Connector Outline
(facing connector)
6
9
8
4
Bypass "on"
UPS "on"
(NO)
(NO)
(NO)
(NO)
(NC)
7
1
2
3
Fault detect signal
(NO)
Input power loss
(battery operation)
LAN manager
(voltage inputs)
Notes:
1)
Pin "switches" are shown in their
inactive states
(ex: if battery voltage is low then
pin 7 will be connected to pin 5 common "GND").
2)
Contacts are rated as follows:
dc:
48V, 0.1A
ac:
30V
rms
(42V-peak), 0.07A (0.1A-peak)
5 System common "GND"
Battery voltage "low"