38
1600XPi Series UPS Installation and Operation Manual – 60616-014
16 Screen Tab: Settings
The Parameter Table in Appendix B lists the 1600XPi Settings parameters that can be viewed in the MONITOR tab.
Example: The Settings parameter
Batt Test Freq
(Battery Test Frequency) can be viewed by USR (User) level and
above. However, only ADM (Administrators) and above can edit )change) the parameter value.
Each key displays a block of relevant command parameters:
Key: Cmd ID - (Range) Parameter type
•
ID –
(000-099) UPS specific information such as serial number, software versions, installation date.
•
Input –
(100-199) Input measured/calculated data such as input voltage, frequency, current, power, over-/under- voltage
settings.
•
Output –
(200-299) Output measured/calculated data such as output voltage, frequency, current, power, over-/under-
voltage settings.
•
Bypass –
(300-399) Bypass data such as configuration, voltage, current, power, OV detection level.
•
DC Bus –
(400-499) Data such as Total voltage, rated voltage, Positive and Negative bus voltages.
•
Batt –
(500-599) Battery voltage, charger status, total discharges, shutdown voltage.
•
Ctrl/Cfg –
(600-699) Control and configuration list system and battery temperatures, system status, startup delay, auto-
transfer window, restart mode.
•
History –
(700-799) History lists metrics like system operation time, total over loads, hi system temp.
•
Disp/Reye –
(800-849) Display specific parameters like Disp. Firmware version, sleep timer, buzzer status, display
calibration points, and RemotEye 4 settings.
(850-859) lists the RemotEye 4 IP address, IP Mask, Status, Baud Rate, datalink status.
On-Line
Main
Monitor
Settings
Records
12:35 PM
INV
HOME
USR
Ctrl/Cfg
History
ID
Input
Output
Bypass
DC Bus
Batt
Disp/Reye
Debug
SETTINGS OPENING SCREEN
96%
100%
Summary of Contents for 1600XPi SERIES
Page 2: ......
Page 6: ...This Page Left Intentionally Blank ...
Page 10: ...This Page Left Intentionally Blank ...
Page 78: ...This Page Left Intentionally Blank ...
Page 88: ...This Page Left Intentionally Blank ...
Page 118: ...This Page Left Intentionally Blank ...
Page 120: ...C2 1600XPi Series UPS Installation and Operation Manual 60616 014 5 2 6 kVA Dimensions ...
Page 121: ...C3 1600XPi Series UPS Installation and Operation Manual 60616 014 8 10 kVA Dimensions ...
Page 122: ...C4 1600XPi Series UPS Installation and Operation Manual 60616 014 14 22 kVA Dimensions ...
Page 130: ......
Page 138: ...This Page Left Intentionally Blank ...
Page 139: ......