INDOOR UNIT DISPLAY
1
1
2
3
4
5
1
ECO (White)
2
Wi-Fi access (White)
3
Hi-Power (White)
4
Timer (White)
5
Operation Mode
- Cool (Blue)
- Heat (Orange)
●
Display brightness can be adjusted, follow procedure on
%
.
Require Wireless LAN connecting adapter which available as accessory.
PREPARATION BEFORE USE
2
Preparing Filters
1. Open the air inlet grille and remove the air filters.
2. Attach the filters. (see detail in the Installation Manual).
Loading Batteries (when use wireless operation.)
1. Remove the slide cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1. Push
by tip of the pencil.
If timer indication is flashing, go to the next step 2.
2. Press
or
: adjust the time.
3. Press
: Set the time.
Remote Control Reset
Push
by tip of the pencil or
1. Remove the batteries.
2. Press
.
3. Insert the batteries.
AIR FLOW DIRECTION
3
1
Press
: Move the louver in
the desired vertical direction.
2
Press
: Swing the air
automatically and press again to stop.
3
For horizontal direction, adjust
manually.
Note
:
●
Do not move the louver manually by others.
●
The louver may automation positioning by some operation mode.
REMOTE CONTROL
4
1
2
3
4
5
6
7
8
9
0
!
@
#
$
%
^
&
*
(
)
-
=
q
w
e
Infrared signal emitter
Memory and Preset button (PRESET)
Start/Stop button
Mode select button (MODE)
Fireplace/8°C button
ECO button
Comfortsleep button(COMFORTSLEEP)
Weekly timer (ON/OFF)
Temp for Weekly timer
On timer button (ON)
Set clock button (CLOCK)
Check button (CHECK)
Filter reset button (FILTER)
Temperature button (TEMP)
Swing louver button (SWING)
Fan speed button (FAN)
Set louver button (FIX)
High power button (Hi POWER)
Power selection/Silent button (P-SEL/SILENT)
Program P1 - P4
Day/Edit button
Setup button (SET)
Off timer button (OFF)
Clear button (CLR)
Reset button (RESET)
1
2
3
4
5
6
7
8
9
0
!
@
#
$
%
^
&
*
(
)
-
=
q
w
e
Note:
●
The provided Remote Controller is a wireless type, which also can be
used as a wire. Please see “How to Connect The Remote Controller
for Wired Operation”, located in installation instruction, in case of wired
control is required.
●
In wire operation, remote controller will return to initial condition
(PRESET, TIMER and CLOCK will return to initial condition) when user
shutdown power supply of Air conditioner.
Note:
●
While Fireplace operation on heating mode, indoor unit fan always runs
and cold air breezing might be occurred.
●
Fireplace and 8°C will operate in Heating mode only.
FIREPLACE1 FIREPLACE 2
Normal
operation
COOLING / HEATING / FAN ONLY OPERATION
5
1. Press
: Select Cool , Heat
or Fan only
.
2. Press
: Set the desired temperature. Min. 17°C, Max. 30°C
Fan Only: No temperature indication
3. Press
: Select AUTO, LOW , LOW+ , MED
,
MED+
, HIGH
or QUIET
.
AUTOMATIC OPERATION
6
To automatically select cooling, heating or fan only operation
1. Press
: Select Auto A.
2. Press
: Set the desired temperature. Min. 17°C, Max. 30°C.
3. Press
: Select AUTO, LOW , LOW+ , MED
,
MED+
, HIGH
or QUIET
.
DRY OPERATION
7
For dehumidification, a moderate cooling performance is controlled
automatically.
1. Press
: Select Dry
.
2. Press
: Set the desired temperature. Min. 17°C, Max. 30°C
Note:
DRY mode fan speed is set to Auto only.
Hi POWER OPERATION
8
To automatically control room temperature and airflow for faster cooling or
heating operation (except in DRY and FAN ONLY mode)
Press
: Start and stop the operation.
ECO OPERATION
9
To automatically control room temperature to save energy (except in DRY
and FAN ONLY mode)
Press
: Start and stop the operation.
Note:
Cooling operation; the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
For heating operation the set temperture will decrease.
Fireplace Operation
Keep indoor unit’s fan blowing continuously during thermo off, to circulate heat
from other sources over the room. There are three setting parameters: Default
setting > Fireplace 1 > Fireplace 2
Fireplace 1:
During thermo off period, the indoor unit’s fan will continue to run by the same
speed, previously selected by end-user.
Fireplace 2:
During thermo off period, the indoor unit’s fan will continue to run at super-low
speed, programmed from factory.
8°C Heating Operation (8°C)
Heat mode operation for keep room temperature (5-13°C) with less of energy
usage.
Fireplace and 8°C Heating Operation
FIREPLACE AND 8°C HEATING OPERATION
10
Normal
operation
1122350218-00_S01_182x257_12p_S_p70_210303.indd 4
21/03/03 9:20:59 AM
Summary of Contents for 18E2AVG-A
Page 8: ...1122350218 00_S01_182x257_12p_S_p70_210303 indd 8 21 03 03 9 21 15 AM ...
Page 9: ...1122350218 00_S01_182x257_12p_S_p70_210303 indd 9 21 03 03 9 21 15 AM ...
Page 10: ...1122350218 00_S01_182x257_12p_S_p70_210303 indd 10 21 03 03 9 21 15 AM ...
Page 11: ...1122350218 00_S01_182x257_12p_S_p70_210303 indd 11 21 03 03 9 21 15 AM ...
Page 12: ...1122350218 1122350218 00_S01_182x257_12p_S_p70_210303 indd 12 21 03 03 9 21 15 AM ...