background image

TEMPORARY OPERATION

18

In case of the misplaced or discharged remote control

 

  Pressing the RESET button, the unit can start or   

    stop without using the remote control.

 

  Operation mode is set on AUTOMATIC operation,  

    preset temperature is 24°C and fan operation is   

  automatic 

speed.

REMOTE CONTROL A-B SELECTION

19

To separate using of remote control for each indoor unit in case of 2 air

conditioners are installed nearly.

Remote Control B Setup.

  1. Press RESET button on the indoor unit to turn the air conditioner ON.

  2. Point the remote control at the indoor unit.

 

3. Push and hold 

 button on the Remote Control by the tip of the

    pencil. “00” will be shown on the display  (Picture 

1

).

 

4. Press 

  during pushing 

. “B”

 

will show on the display and

    “00” will disappear and the air conditioner will turn OFF. The Remote

  

Control B is memorized  (Picture 

2

).

Note:  1. Repeat above step to reset Remote Control to be A.

      2. Remote Control A has not “A” display.

      3. Default setting of Remote Control from factory is A.

1

2

OPERATION AND PERFORMANCE

20

1. Three-minute protection feature: To prevent the unit from being activated  

 

  for 3 minutes when suddenly restarted or switched to ON.

2. Preheating operation: Warm up the unit for 5 minutes before the heating  

 

  operation starts.

3. Warm air control: When the room temperature reaches the set 

  temperature, the fan speed is automatically reduced and the outdoor unit 

 

will stop.

4. Automatic defrosting: Fans will stop during defrost operation.

5. Heating capacity: Heat is absorbed from outdoors and released into 

 

the room. When the outdoor temperature is too low, use another 

 

recommended heating apparatus in combination with the air conditioner.

6. Consideration for accumulated snow: Select the position for outdoor unit 

  where it will not be subjected to snow drifts, accumulation of leaves or 

  other seasonal debris.

7. Some minor cracking sound may occur when unit operating. This is 

  normal because the cracking sound may be caused by expansion/

  contraction of plastic. 

Note:

 Item 2 to 6 for Heating model

Air conditioner operating conditions

Temp.

Operation

Outdoor Temperature

Room Temperature

Heating

-15°C ~ 24°C

0 ~ 28°C

Cooling

-10°C ~ 46°C

21°C ~ 32°C

Dry

-10°C ~ 46°C

17°C ~ 32°C

MAINTENANCE

21

 Firstly, turn off the circuit breaker.

Indoor Unit and Remote Control

 

  Clean the indoor unit and the remote control with a wet cloth when 

  needed.

 

  No benzine, thinner, polishing powder or chemically-treated duster.

Air filters

Clean every 2 weeks.

  

1. Open the air inlet grille.

   2. Remove the air filters.

   3. Vacuum or wash and then dry them.

   4. Reinstall the air filters and close the air inlet grille.

TROUBLESHOOTING (CHECK POINT)

22

WEEKLY TIMER OPERATION

23

The unit does not operate.

Cooling or Heating is abnormally low.

  The power main switch is

    turned off.

  The circuit breaker is 

    activated to cut off the power 

supply.

  Stoppage of electric current

  ON timer is set.

  The filters are blocked with dust.

  The temperature has been set 

    improperly.

  The windows or doors are opened.

  The air inlet or outlet of the outdoor 

     unit is blocked.

  The fan speed is too low.

  The operation mode is FAN or DRY

  POWER SELECTION function is 

    set 75% or 50% 

(This function is 

    depend on remote controller)

.

How to set WEEKLY TIMER

1.  Press 

 to enter WEEKLY TIMER setting.

2.  Press 

 to select desired day in sequence. 

  The sequence of day symbol appears on the LCD.

3.  Press 

 to select the program number. 

  ●  The program 1 is ready for setting while 

 is 

    pressed PG-1 appears on the LCD. 

  ●  Press 

 to change the program number in 

    the sequence program 1 to program 4.

4.  Press 

 or 

 to select the desired time. 

  ●  The time can be set between 0:00 and 23:50 in 

    10 minute intervals. 

  ●  Press and hold the button to change setting time 

    for 1 hr. 

  ●  Only one of ON or OFF timer can be set on each  

  program.

5.  Press 

 to select desired operation.

6. Press 

 or 

 to select desired temperature. 

  ●  The temperature can be set between 17°C and 

    30°C.

7. Press 

 to select the desired fan speed.

8.  Add operations, if required. 

  ●  Press 

 to use 8°C operation. 

    (Notes: Fireplace cannot select and memorize in 

    weekly function)  

  ●  Press 

 to use ECO operation. 

  ●  Press 

 to use Hi POWER operation. 

  ●  Press 

 to use Silent operation.

Blink

SU      MO     TU      WE      TH     FR     SA

ON timer display

*OFF timer is used to stop the air conditioner only.

  The display does not show Operation mode, Temperature, 

  Fan speed and others.

OFF timer display*

WEEKLY SUMO

TUWETHFRSA

(All day)

1122350218-00_S01_182x257_12p_S_p70_210303.indd   6

21/03/03   9:21:04 AM

Summary of Contents for 18E2AVG-A

Page 1: ...NUAL AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS 07 10 13 16 18E2KVG A Outdoor unit RAS 07 10 13 16 18E2AVG A 1122350218 1122350218 00_S01_182x257_12p_S_p70_210303 indd 1 21 03 03 9 20 59 AM ...

Page 2: ...r warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner and disconnect the power supply or turn off the breaker This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have...

Page 3: ...e unit with water It may cause an electric shock Do not use this air conditioner for other purposes such as preserving food breeding animal etc Do not step or put anything on the indoor outdoor unit It may cause an injury or damage the unit Do not touch aluminium fin because it may cause an injury Before cleaning the unit turn off the main switch or the circuit breaker When the unit won t be used ...

Page 4: ...initial condition PRESET TIMER and CLOCK will return to initial condition when user shutdown power supply of Air conditioner Note While Fireplace operation on heating mode indoor unit fan always runs and cold air breezing might be occurred Fireplace and 8 C will operate in Heating mode only FIREPLACE1 FIREPLACE 2 Normal operation COOLING HEATING FAN ONLY OPERATION 5 1 Press Select Cool Heat or Fan...

Page 5: ...he desired ON timer Press Set the desired OFF timer 2 Press Set the timer Press Set the timer 3 Press Cancel the timer Press Cancel the timer Note Keep the remote control in accessible transmission to the indoor unit otherwise the time lag of up to 15 minutes will occur The setting will be saved for the next same operation PRESET OPERATION 14 Set your preferred operation for future use The setting...

Page 6: ...ture Heating 15 C 24 C 0 28 C Cooling 10 C 46 C 21 C 32 C Dry 10 C 46 C 17 C 32 C MAINTENANCE 21 Firstly turn off the circuit breaker Indoor Unit and Remote Control Clean the indoor unit and the remote control with a wet cloth when needed No benzine thinner polishing powder or chemically treated duster Air filters Clean every 2 weeks 1 Open the air inlet grille 2 Remove the air filters 3 Vacuum or...

Page 7: ...TIMER operation Press while WEEKLY is displayed on the LCD The WEEKLY indicator will disappear from the LCD However the program will remain in the remote control The TIMER lamp goes off To reactivate the WEEKLY TIMER operation again press again LCD shows the next program The program after reactivation is related to the clock time To delete programs The individual program 1 Press The day of the wee...

Page 8: ...1122350218 00_S01_182x257_12p_S_p70_210303 indd 8 21 03 03 9 21 15 AM ...

Page 9: ...1122350218 00_S01_182x257_12p_S_p70_210303 indd 9 21 03 03 9 21 15 AM ...

Page 10: ...1122350218 00_S01_182x257_12p_S_p70_210303 indd 10 21 03 03 9 21 15 AM ...

Page 11: ...1122350218 00_S01_182x257_12p_S_p70_210303 indd 11 21 03 03 9 21 15 AM ...

Page 12: ...1122350218 1122350218 00_S01_182x257_12p_S_p70_210303 indd 12 21 03 03 9 21 15 AM ...

Reviews: