•  Check the fl are nut 

connections for the gas 
leak with a gas leak 
detector or soap water.

Gas Leak Test

Check places for fl are nut connection 
(Indoor unit)

Check places for the outdoor unit.

Valve cover

Remote control selector switch

  When two indoor units are installed in the same room or adjacent two 

rooms, if operating a unit, two units may receive the remote control 
signal simultaneously and operate. In this case, the operation can 
be preserved by setting either one indoor unit or remote control to B 
setting (Both are set to A setting in factory shipment).

  The remote control signal is not received when the settings of indoor 

unit and remote control are different.

  There is no relation between A setting/B setting and A room/B room 

when connecting the piping and cables.

When two indoor units are installed in the separated rooms, it is not 
necessary to change the selector switches.

Setting of Remote Control

Selector Switch

“B” Display

“00” Display

PRESET

FAN

Remote Control A-B Selection

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed nearly.

Remote Control B Setup.

1. Push and hold 

 button on the Remote Control by the tip of the pencil.

   “00” will be shown on the display.

2. Press 

 during pushing 

. “B” will show on the display and “00” will 

disappear and the air conditioner will turn OFF. The Remote Control B is 
memorized.

Note  :  1. Repeat above step to reset Remote Control to be A.
 

  2. Remote Control A has not “A” display.

 

  3. Default setting of Remote Control from factory is A.

Unit B setup. 

  Press and hold MODE button for more than 20 seconds. 
  When A setup changed to B setup : 5 beeps will sound and operation 

lamp blinks for 5 seconds. 

  When B setup changed to A setup : 5 beep will sound.

OTHERS

OTHERS

Test Operation

Auto Restart Setting

How to set the Auto Restart

1. Press and hold OPERATION button on the indoor unit for 3 seconds to set 

the operation (3 beep sound and OPERATION lamp blink 5 time/sec for 5 
seconds).

2. Press and hold OPERATION button on the indoor unit for 3 seconds to 

cancel the operation (3 beep sound but OPERATION lamp does not blink).

 

 In case of ON timer or OFF timer are set, it dose not activate.

This product is designed so that, after a power failure, it can restart 
automatically in the same operating mode as before the power failure.

To switch the TEST RUN (COOL) mode, press OPERATION button for 10 
seconds (The beeper will make a short beep).

Information

The product are shipped with Auto Restart function in the off position. 
Turn it on as required.

9

Summary of Contents for 18UFV-E1

Page 1: ...8SAV E RAS 3M26GAV E1 RAS 4M23SAV E RAS 4M27GAV E1 RAS 5M34UAV E AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH PORTUGUÊS POLSKI ČESKY PУCСКИЙ HRVATSKI MAGYAR TÜRKÇE NEDERLANDS ΕΛΛΗΝΙΚΑ SVENSKA SUOMI NORSK DANSK ROMÂNĂ БЪЛГАРСКИ EESTI LATVISKI SLOVENČINA SLOVENŠČINA ...

Page 2: ...enie Instalacji Rurowej Czynnika Chłodniczego 7 n Usuwanie Powietrza 8 n Podłączenie Okablowania 8 n Prace Elektryczne 8 INNE 9 n Próba Gazoszczelności 9 n Ustawianie Przełącznika Wyboru Pilota 9 n Ustawienia Przełącznika A B Wyboru Pilota 9 n Próba Działania 9 n Włączanie Funkcji Automatycznego Wznawiania Pracy Auto Restart 9 PL OBSAH BEZPEČNOSTNÍ OPATŘENÍ 1 SCHÉMA INSTALACE VNITŘNÍ A VENKOVNÍ JE...

Page 3: ...talare Opţionale 3 UNITATE INTERIOARĂ 4 n Locul de Instalare 4 n Executarea unei Găuri şi Montarea Plăcii de Instalare 4 n Cum se Instalează Unitatea Interioară 5 n Instalarea Mascată 6 UNITATEA EXTERIOARĂ 7 n Locul de Instalare 7 n Măsuri de Precauţie privind Instalarea în Regiuni cu ninsori Abundente şi Temperaturi Scăzute 7 n Drenarea Apei din Unitatea Exterioară 7 n Racordarea Ţevilor de lichi...

Page 4: ...s of charging port connecting sections on the main unit are different from those for the conventional refrigerant and different size tools are also required For connecting pipes use new and clean piping materials with highpressure withstand capabilities designed for R410A only and ensure that water or dust does not enter Moreover do not use any existing piping as its pressure withstand may be insu...

Page 5: ...t enough or installation of the unit is improper the unit may fall and result in injury Electrical work must be performed by a qualified electrical engineer in accordance with the code governing such installation work internal wiring regulations and the manual A dedicated circuit and the rated voltage must be used Insufficient power supply or improper installation may cause electrical shock or fir...

Page 6: ...If it is necessary to drain the defrost water attach drain nipple and cap water proof to the bottom plate of the outdoor unit before installing it Fixing bolt arrangement of outdoor unit RAS 10 13 18SAV Series 3 Batteries 8 Pan head wood screw 4 Remote control holder Do not allow the drain hose to get slack Make sure to run the drain hose sloped downward The auxiliary piping can be connected to th...

Page 7: ...hole brim ring sold separately A place which provides the spaces around the indoor unit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened In case of block brick concrete or similar type walls make 5 mm holes in the wall Insert clip anch...

Page 8: ... Do not form the drain hose into a wavy shape Do not put the drain hose end into water Do not put the drain hose end in the drainage ditch Drainage 1 Run the drain hose sloped downwards Wiring connection Wiring of the connection cable is necessary to remove the front panel 1 Remove the terminal cover and cord clamp 2 Insert the connecting cable according to the local rule into the pipe hole on the...

Page 9: ...or more 20 to 30 240 to 250 Floor Wall Side view Unit mm 4 In case of lattice establishment Follow the following figure make sure to keep enough distance between lattice frame and wall Be sure to switch to wall burying mode The lattice should be make of wood Between the air inlet and outlet should be devided with partition board Be sure to establish the open part for RECEIVER The open part of latt...

Page 10: ...A place full of machine oil A saline place such as the coast A place full of sulfide gas A place where high frequency waves are likely to be generated such as from audio equipment welders and medical equipment Strong wind Snow protection plate Snow protection hood At least 50 cm Snow accumulation line Holding frame Front Anchor bolts Install at least 50 cm above the snow accumulation line Do not u...

Page 11: ...en fully the valve stem of the packed valves both gas and liquid sides 7 Remove the charging hose from the service port 8 Securely tighten the caps on the packed valves VACUUMING Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump Do not use the refrigerant in the outdoor unit For details see the manual of the vacuum pump Tightening torque for connection of flare pi...

Page 12: ...ote Control by the tip of the pencil 00 will be shown on the display 2 Press during pushing B will show on the display and 00 will disappear and the air conditioner will turn OFF The Remote Control B is memorized Note 1 Repeat above step to reset Remote Control to be A 2 Remote Control A has not A display 3 Default setting of Remote Control from factory is A Unit B setup Press and hold MODE button...

Page 13: ...1112150201 1 ...

Reviews: