10. INSTALLATION PROCEDURE
10-1. Installation Diagram of Indoor and Outdoor Units
A
C
L
Rear
left
Saddle
100 mm or more
100
mm or more
6
00 mm or more
60
0 mm or more
Pure Air Pur
ifier
(Attach to the f
ront panel.)
Air filter
50
mm or more
170 mm or mor
170 mm or more
Hook
Hook
Wall
For the rear left and left piping
8 mm thick heat resisting
polyethylene foam
Insulate the refrigerant pipes separately
with insulation, not together.
Right
Left
Rear right
The auxiliary piping can be connected
to the left, rear left, rear right, right,
bottom right or bottom left.
Make sure to run the drain hose
sloped downward.
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
Cut the
piping hole
sloped slightly.
Bottom right
Bottom left
Do not allow the drain hose to get slack.
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Before installing the wireless remote controller
3 Batteries
2 Wireless remote controller
2 Wireless remote controller
4 Remote controller
holder
8
Pan head
wood screw
5 Filter
6 Filter
3 Batteries
Extension drain hose
(Not available, provided by installer)
Vinyl tape
Apply after carrying
out a drainage test.
Pure Air Purifier
SKVR only
1 Installation