ELECTRICAL ADJUSTMENTS
D-1
1. ADJUSTMENT PROCEDURE
Read and perform these adjustments when repairing the
circuits or replacing electrical parts or PCB assemblies.
CAUTION
•
•
•
•
Use an isolation transformer when performing any service
on this chassis.
Before removing the anode cap, discharge electricity
because it contains high voltage.
When removing a PCB or related component, after
unfastening or changing a wire, be sure to put the wire
back in its original position.
When you exchange IC and Transistor for a heat sink,
apply the silicon grease on the contact section of the heat
sink. Before applying new silicon grease, remove all the
old silicon grease. (Old grease may cause damages to the
IC and Transistor.)
2. BASIC ADJUSTMENTS
Prepare the following measurement tools for electrical
adjustments.
2-1: CONSTANT VOLTAGE
1.
2.
3.
4.
Place the set with Aging Test for more than 5 minutes.
Set condition is AV MODE without signal.
Connect the digital voltmeter to the TP003.
Adjust the VR502 until the digital voltmeter is 135
±
1V.
1. Oscilloscope
2. Digital Voltmeter
3. Multi-sound Generator
4. Pattern Generator
On-Screen Display Adjustment
1. In the condition of NO indication on the screen.
Press the VOL. DOWN button on the set and the Channel
button (9) on the remote control for more than 1 second to
appear the adjustment mode on the screen as shown in
Fig. 1-1.
Fig. 1-1
3.
4.
Use the Channel UP/DOWN button or Channel button
(0-9) on the remote control to select the options shown
in Fig. 1-2.
Press the MENU button on the remote control to end the
adjustments.
TV
00 OSD H 27
2-4: FOCUS
1.
2.
3.
Receive the monoscope pattern.
Turn the Focus Volume fully counterclockwise once.
Adjust the Focus Volume until picture is distinct.
2-3: WHITE BALANCE
NOTE: Adjust after performing CUT OFF adjustment.
1.
2.
3.
4.
5.
6.
7.
Place the set with Aging Test for more than 10 minutes.
Receive the gray scale pattern from the Pattern Generator.
Using the remote control, set the brightness and contrast
to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (12) on the remote control to
select “R. BIAS”.
Press the CH. UP/DOWN button on the remote control to
select the “R. BIAS”, “G. BIAS”, “B. BIAS”, “B. DRIVE” or
“G. DRIVE”.
Adjust the VOL. UP/DOWN button on the remote control
to whiten the R. BIAS, G. BIAS, B. BIAS, B. DRIVE, and
G. DRIVE at each step tone sections equally.
Perform the above adjustments 5 and 6 until the white
color is looked like a white.
2-2: CUT OFF
1.
2.
3.
Place the set with Aging Test for more than 15 minutes.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (01) on the remote control to
select "CUT OFF".
Adjust the Screen Volume until a dim raster is obtained.
2-5: HORIZONTAL PHASE
1.
2.
3.
4.
Receive the monoscope pattern.
Using the remote control, set the brightness and contrast
to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (03) on the remote control to
select “H. PHAS”.
Press the VOL. UP/DOWN button on the remote control
until the SHIFT quantity of the OVER SCAN on right and
left becomes minimum.
FUNCTION
E/W CORNER
E/W TRAPEZIUM
LEVEL
SEPARATION1
SEPARATION2
DRIVE R COOL
DRIVE B COOL
R BIAS COOL
G BIAS COOL
B BIAS COOL
DRIVE R WARM
DRIVE B WARM
R BIAS WARM
G BIAS WARM
B BIAS WARM
FUNCTION
OSD H
CUT OFF
H. VCO
H. PHASE
V. SHIFT
H. SIZE
V. SIZE
V. LINEARITY
VS CORRECTION
DRIVE R MEDIUM
DRIVE B MEDIUM
R BIAS MEDIUM
G BIAS MEDIUM
B BIAS MEDIUM
BRIGHT MAX
NO.
00
01
02
03
05
06
07
08
09
10
11
12
13
14
15
Fig. 1-2
NO.
31
32
33
34
35
51
52
53
54
55
56
57
58
59
60
FUNCTION
BRIGHT CENT
BRIGHT MIN
CONTRAST MAX
CONTRAST CENT
CONTRAST MIN
COLOR MAX
COLOR CENTER
COLOR MIN
TINT
SHARPNESS
Cb DELAY FINE
Cr DELAY FINE
Cb PEDESTAL ADJ
Cr PEDESTAL ADJ
E/W PARABOLA
NO.
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30