ELECTRICAL ADJUSTMENTS
D-3
1.
2.
3.
4.
5.
6.
7.
8.
9.
Set the multi-sound signal generator L-ch=1KHz, R-ch
=Non input and receive the RF.
Connect the oscilloscope to the Audio Out Jack (R-ch).
Press the AUDIO SELECT button on the remote control
to set to the stereo mode.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (34) on the remote control to
select “SEP 1”.
Press the VOL. UP/DOWN button on the remote control
to adjust it until the R-ch output becomes minimum.
Set the multi-sound signal generator L-ch=Non input,
R-ch=1KHz and receive the RF.
Connect the oscilloscope to the Audio Out Jack (L-ch).
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (35) on the remote control to
select “SEP 2”.
Press the VOL. UP/DOWN button on the remote control
to adjust it until the L-ch output becomes minimum.
Method (2)
2-15: BRIGHT CENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Receive the monoscope pattern. (RF Input)
Using the remote control, set the brightness and contrast
to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (16) on the remote control to
select "BRI CENT".
Press the VOL. UP/DOWN button on the remote control
until the white 0% is starting to be visible
Receive the monoscope pattern. (Audio Video Input)
Press the TV/VIDEO button on the remote control to set
to the AV mode. Then perform the above adjustments
2~4.
Press the TV/VIDEO button on the remote control to set
to the CS mode.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (16) on the remote control to
select "BRI CENT".
Press the VOL. UP/DOWN button on the remote
control until the brightness step No. becomes “60”.
Receive a broadcast and check if the picture is normal.
2-16: TINT/COLOR CENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
Receive the color bar pattern.
Connect the oscilloscope to TP806.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (24) on the remote control to
select "TINT".
Press the VOL. UP/DOWN button on the remote control
until the section "A" becomes as straight line
(Refer to Fig. 2-1)
Press the VOL. UP/DOWN button on the remote control
until the 7 step up becomes as straight line
Connect the oscilloscope to TP804.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (22) on the remote control to
select "COL.CENT".
Press the VOL. UP/DOWN button on the remote control
until the red color level is adjusted to 120
±
10% of the
white level. (Refer to Fig. 2-2)
Receive the color bar pattern. (Audio Video Input)
Press the TV/VIDEO button on the remote control to set to
the AV mode. Then perform the above adjustments 2~8.
Press the TV/VIDEO button on the remote control to set to
the CS mode.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (24) on the remote control to
select "TINT".
Press the VOL. UP/DOWN button on the remote
control until the tint step No. becomes “50”.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (22) on the remote control to
select "COL.CENT".
Press the VOL. UP/DOWN button on the remote
control until the color step No. becomes “65”.
Receive a broadcast and check if the picture is normal.
Fig. 2-2
white 100%
red 120%
Fig. 2-1
"A"