SETTING & ADJUSTING DATA
29"
HIGH VOLTAGE AT ZERO BEAM:
(A)
32.8 kV
MAX HIGH VOLTAGE:
(B)
33.0 kV
AC VOLTAGE
(C)
110~240 V
CHAPTER 2
SPECIFIC INFORMATIONS
SAFETY INSTRUCTIONS
Table-1
SERVICE MODE
ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:
DESIGN MODE
ADJUSTING ITEMS AND DATAS IN THE DESIGN MODE:
Item
Name of adjustment
Preset Data
Data
Remarks
OPT 1
OPTION 1
05H
22H
OPT 2
OPTION 2
10H
1DH
Table-3
Item
Adjustment
Reference data
RCUT
GCUT
BCUT
GDRV
BDRV
BRTC
COLC
TNTC
COLP
COLS
SCNT
HPOS
VPOS
HIT
VLIN
WID
PARA
TRAP
BELL
SRY
SBY
R CUTOFF H
G CUTOFF H
B CUTOFF H
G DRIVE H
B DRIVE H
SUB BRIGHT CEN
SUB COLOR CEN NTSC
SUB TINT CEN
SUB COLOR CEN PAL
SUB COLOR CEN SECAM
SUB CONTRAST
50Hz H-POSITION
V-POSITION
HEIGHT
V-LINEARITY
PICTURE WIDTH
E-W PARABOLA
TRAPEZIUM
SECAM BELL FILTER
SECAM R-Y
SECAM-B-Y
04H
04H
04H
RDRV
R DRIVE H
07H
07H
07H
80H
80H
40H
F6H
F6H
07H
12H
03H
20H
07H
2CH
2BH
0BH
01H
08H
08H
Table-