TD - Series
- 18 -
TD Series
Digital Solid State Soft Starter 48 - 1250A
5.4.4 Kick Start Mode Functions
5.4.5 Decel Mode Functions
5.4.6 Protection Features
Fn
Group
Function
Adjustment
Range
Setting
Increments
Factory
Setting
Section
F025
Deceleration Ramp
0=Disabled / Coast to Stop
1=Enabled (except in event of OL Trip)
2=Enabled (continued Decel on OL Trip)
1
0 (Disabled)
5.5.5
F026
Begin Decel Level (BDL)
0 - 100 %
1%
60%
5.5.5
F027
Decel Shut Off Voltage
0 to (BDL minus 1)%
1%
30%
5.5.5
F028
Decel Ramp Time
1 - 60 Seconds
1 second
10 seconds
5.5.5
F029
Reserved
Reserved
Reserved
Reserved
5.5.5
De
ce
l
M
ode
Fn
Group
Function
Adjustment
Range
Setting
Increments
Factory
Setting
Section
F030
Current Imbalance Trip
0=Disabled
1=Enabled
1
0 (Disabled)
5.5.6
F031
Current Imbalance Trip %
5 - 30%
1%
10%
5.5.6
F032
Current Imbalance Trip Delay
1 - 20 seconds
1 second
2 seconds
5.5.6
F033
Over Current / Shear Pin Trip
0=Disabled
1=Enabled
1
0 (Disabled)
5.5.6
F034
Over Current / Shear Pin Trip %
50 - 300% (note1)
1%
125%
5.5.6
F035
Over Current Trip Delay
1 - 20 seconds
1 second
1 second
5.5.6
F036
Under Current Trip
0=Disabled
1=Enabled
1
0 (Disabled)
5.5.6
F037
Under Current Trip %
10 - 90% (note1)
1%
40%
5.5.6
F038
Under Current Trip Delay
1 - 60 seconds
1 second
2 seconds
5.5.6
F039
Coast Down Lockout Timer
0=Disabled
1=Enabled
1
0 (Disabled)
5.5.6
F040
Coast Down Lockout Time
1 - 60 minutes
1 minute
5 minutes
5.5.6
F041
Starts per Hour Lockout
0=Disabled
1=Enabled
1
0 (Disabled)
5.5.6
F042
Maximum Starts per Hour
1 - 10
1
2
5.5.6
F043
Time Between Starts Lockout
0=Disabled
1=Enabled
1
0 (Disabled)
5.5.6
F044
Minimum Time Between Starts
1 - 60 minutes
1 minute
15 minutes
5.5.6
F045
Coast Down Timer Value
1 - 3600 Seconds
View Only
0
5.5.6
F046
Starts per Hour Timer Value
1 - 3600 Seconds
View Only
0
5.5.6
F047
Starts per Hour Count Value
1 - 10 Starts
View Only
0
5.5.6
F048
Time Value Between Starts
1 - 3600 Seconds
View Only
0
5.5.6
F049
Thermal Capacity to Start
0 - 100 % Thermal Capacity
View Only
0
5.5.6
P
rot
ec
tion Featu
res
Fn
Group
Function
Adjustment
Range
Setting
Increments
Factory
Setting
Section
F022
Kick Start
0=Disabled
1=Enabled
1
0 (Disabled)
5.5.4
F023
Kick Voltage
10 - 100%
1%
65%
5.5.4
F024
Kick Time
0.1 - 2 Seconds
0.1 second
0.8 seconds
5.5.4
Kic
k Sta
rt
Mode