– 19 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
CIRCUIT CHECKS
HIGH VOLTAGE CHECK
CAUTION: There is no HIGH VOLTAGE ADJUSTMENT on
this chassis. Checking should be done following
the steps below.
1. Connect an accurate high voltage meter to the anode of
the picture tube.
2. Turn on the receiver. Set the BRIGHTNESS and CON-
TRAST to minimum (zero beam current).
3. High voltage must be measured below (B) kV.
Refer to table-1 for high voltage (B).
(See SETTING & ADJUSTING DATA on page 20)
4. Vary the BRIGHTNESS to both extremes to be sure the
high voltage does not exceed the limit under any condi-
tions.
CAUTION:
When the following parts fail, check the High Voltage after
replacing.
FS CIRCUIT CHECK
The Fail Safe (FS) circuit check is indispensable for the final
check in servicing. Checking should be done following the
steps below.
1. Turn the receiver on.
2. Temporarily short TP- (R) and TP- (X) on the DEF/POWER
Board with a jumper wire.
Raster and sound will disappear.
3. The receiver must remain in this state even after removing
the jumper wire. This is the evidence that the FS circuit is
functioning properly.
4. To obtain a picture again, temporarily turn the receiver off
and allow the FS circuit more than 5 seconds to reset. Then
turn the receiver on to produce a normal picture.
Location
No.
Name
50"~65"
T461
C407
C408
C445
C446
C447
C448
C449
←
5100pF,
±
3%
0.022
µ
F,
±
3%
0.022
µ
F,
±
5%
0.012
µ
F,
±
5%
5600pF,
±
3%
←
←
ANODE VOLTAGE MEASURING METHOD
CAUTION: Take extra precaution when measuring this high
voltage. High voltages are also present in
surrounding circuit boards (CRT DRIVE assem-
bly, DEFLECTION assembly, and POWER
SUPPLY assembly).
1. Disconnect the FBT anode cable as outlined below. Meas-
ure high voltage at the point where the cable enters the
FBT.
2. Holding the rubber cover firmly, turn it counterclockwise
and check that the lock has been disengaged. (See Fig. b
on page 8.)
3. Determine the extent of the rubber cover before discon-
necting the cable.
4. Pull straight up the anode cable to disconnect.
5. When reconnecting the cable, proceed in the reverse order.
After reconnecting, tug on the cable to check that it is secure.
Troubleshooting Guide for Fail Safe Circuit
Check that the set returns to normal operation when
pin 12 of Z801 is grounded with jumper wire.
Check the voltage across
Capacitor C419 is
approximately (
C)
volts.
Refer to table –4 for
fall safe voltage (
C)
.
Faulty power
circuit or hori-
zontal circuit.
Defective Fail Safe Circuit
(See SETTING & ADJUSTING
DATA on page 20)
YES
NO
NO
YES
TFB3088AD
4300pF,
±
3%
0.027
µ
F,
±
5%
0.015
µ
F,
±
5%
0.011
µ
F,
±
5%
6200PF,
±
3%
8200PF,
±
5%
1000PF,
±
3%
40", 43"
Descriptions
Flyback
Capacitor
Capacitor
Capacitor
Capacitor
Capacitor
Capacitor
Capacitor
Summary of Contents for 65H80
Page 24: ... 24 GENERAL ADJUSTMENTS SPECIFIC INFORMATIONS THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 25: ...CIRCUIT BLOCK DIAGRAM 25 26 ...
Page 54: ... 56 SPECIFIC INFORMATIONS THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 55: ... 57 58 SIGNAL CONV BOARD PB9581G BOTTOM FOIL SIDE ...
Page 56: ... 59 60 DEF POWER BOARD PB9582D BOTTOM FOIL SIDE ...
Page 57: ... 61 62 A V BOARD PB9583A BOTTOM FOIL SIDE ...
Page 58: ... 63 64 HYPER PRO BOARD PB9584A BOTTOM FOIL SIDE DPC BOARD PB9602A BOTTOM FOIL SIDE ...
Page 59: ... 65 CRT D RED BOARD PB9586ZA 1 BOTTOM FOIL SIDE CRT D GRN BOARD PB9586ZA 2 BOTTOM FOIL SIDE ...
Page 60: ... 66 CRT D BLU BOARD PB9586ZA 3 BOTTOM FOIL SIDE D COVER BOARD PB9585E BOTTOM FOIL SIDE ...
Page 61: ... 67 SVM R BOARD PB9586ZA 4 BOTTOM FOIL SIDE SVM G BOARD PB9586ZA 5 BOTTOM FOIL SIDE ...
Page 62: ... 68 SVM B BOARD PB9586ZA 6 BOTTOM FOIL SIDE FRONT CON BOARD PB9121B BOTTOM FOIL SIDE ...
Page 63: ... 69 SRS BOARD PB9587 BOTTOM FOIL SIDE ...
Page 65: ... 71 SPECIFIC INFORMATIONS MEMO ...