136
ACE-tronics G9 ASD Installation and Operation Manual
Stopping Time at Stop Limit-Switch DOWN
Program
Crane/Hoist
Limit Switch Control
A Stop command is initiated upon activation of the Lower-Limit Stop Limit-
Switch.
This parameter sets the Decel rate to be used upon activation of the Lower-
Limit Stop Limit-Switch.
Direct Access Number — F286
Parameter Type — Numerical
Factory Default — 1.5
Changeable During Run — No
Minimum — 0.0
Maximum — 25.0
Units — Seconds
Preset Speed 8
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1000 and is
identified as Preset Speed 8. The binary number is applied to I1 – I4 of the
ACE G9-120V-PCB to output the Preset Speed (see
F018
for additional
information on this parameter).
Direct Access Number — F287
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (
F013
)
Maximum — Upper Limit (
F012
)
Units — Hz
Preset Speed 9
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1001 and is
identified as Preset Speed 9. The binary number is applied to I1 – I4 of the
ACE G9-120V-PCB to output the Preset Speed (see
F018
for additional
information on this parameter).
Direct Access Number — F288
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — Lower Limit (
F013
)
Maximum — Upper Limit (
F012
)
Units — Hz
Preset Speed 10
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1010 and is
identified as Preset Speed 10. The binary number is applied to I1 – I4 of the
ACE G9-120V-PCB to output the Preset Speed (see
F018
for additional
information on this parameter).
Direct Access Number — F289
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (
F013
)
Maximum — Upper Limit (
F012
)
Units — Hz
Preset Speed 11
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1011 and is
identified as Preset Speed 11. The binary number is applied to I1 – I4 of the
ACE G9-120V-PCB to output the Preset Speed (see
F018
for additional
information on this parameter).
Direct Access Number — F290
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (
F013
)
Maximum — Upper Limit (
F012
)
Units — Hz
Preset Speed 12
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1100 and is
identified as Preset Speed 12. The binary number is applied to I1 – I4 of the
ACE G9-120V-PCB to output the Preset Speed (see
F018
for additional
information on this parameter).
Direct Access Number — F291
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (
F013
)
Maximum — Upper Limit (
F012
)
Units — Hz
F286
F291
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com