CN3 connector (bottom left). Light indicator.
Pin Name
Description
1 V24
Power 24V
2 LG
GREEN light (Always ON)
3 LA
ORANGE light (IN OPERATION)
4 LR
RED light (ERROR)
Notes:
It is possible to use these signals to check APLEX status but always respecting the
maximum voltage and current values.
This signals are designed to be used with original APLEX light indicator. If used for
any other application, you have to take into account the maximum consumption supported
by the outputs and the use made of the 24V line. This line is the internal power of the
applicator, so you have to take good care of both consumption and noise injection, not to
vary the terms of the CE certificate, or disrupt the operation of the applicator.
Output circuit:
The load is always between the 24V signal and the corresponding
OUT.
Each output supports a maximum of 25mA, though 60mA should never
be exceeded in all three. No supports inductive loads (relays, solenoid
valves, etc.)