– 19 –
FILE NO. SVM-04007
5-2. RAS-18UKHP-ES3 / RAS-18UAH-ES3
Note :
•
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
*1
•
During heating overload operation, a value for the high temperature limit control operation is included.
Ambient temp.
conditions DB/WB
(
°
C)
Indoor
Outdoor
Standard
2.7
45.0
High
20/
–
7/6
Heating Overload*1
3.0 ~ 3.8
49.0 ~ 58.0
Low
27/
–
24/18
Low temperature
2.0
34.0
High
20/
–
–
10/
–
10
Standard
0.9
10.0
High
27/19
35/24
Cooling Overload
1.0
15.0
High
32/23
43/26
Low temperature
0.6
1.0
Low
21/15
21/15
Fan speed
(indoor)
50Hz
Standard
pressure
P
(MPaG)
Surface temp. of heat
e
xchanger interchanging
pipe
T1
(°
C)
Indoor unit
Cross flow fan
Cooling
Heating
4-way valve
Heating Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
PA225X3F-4L
Cooling
Heating
Mark(
)means check points of Gas Leak.
O.D.:12.7mm
O.D.:6.35mm
Cooling
Heating
Packed valve
(
∅
12.7)
Packed valve
(
∅
6.35)
0.39m
(Connecting pipe)
∅
12.7
0.49m
(Connecting pipe)
∅
6.35
T1
P
Refrigerant
R410A 1.3 kg
Accumulator
Evaporator
Capillary tube
∅
1.7x700
s
Capillary tube
∅
1.0x1500
s
RAS-18UKHP-AS3 / RAS-18UAH-AS3