6-12
EM18-33010A
6. DIAG. TEST OPERATION
NOTES: 1. If the head broken element check results in ‘HEAD ERROR’, the print head must be
replaced after referring to Section 2.6 Replacing the Print Head.
2. After replacing the print head, clear the maintenance counter as described in Section
6.6.1 and perform a test print in Section 6.4 TEST PRINT MODE.
(Revision Date Jul. 03, ’97)
6.2 SELF TEST MODE
6.2.3
Head Broken Element Check
The printer automatically performs the head broken element check. The result of the head broken
element check is indicated in the display.
< 1
D I A G N O S T I C
V 1 . 0 A
>
Power off
C H
C K I N G
E
N O
M A L
E N D
R
H E
D
E R R O R
A
T H
R M A L
H E A D
C H E C K
E
Press the [FEED] key twice.
Press the [PAUSE] key.
Head broken element check
takes about 10 seconds.
(See NOTE 1 and 2.)
Press the [PAUSE] key.
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [PAUSE] key twice.
[ ]
Summary of Contents for B-570