CHAPTER 4 TRANSMISSION SEQUENCE
B-EP
Series
4-14
(4)
When interrupting communication while the 2nd label command is running, and then
retransmitting the 2nd label data from the beginning,
1st transmission:
{AY;+00,1,3|}
{D0130,0480,0100|}
{C|}
{LC;0010,0010,0470,0060,1,2|}
1st label data
{PC00;0030,0050,2,1,a,00,B,+0000000000|}
{RC00;2inch 0001|}
{XS;I,0001,0000C2011|}
{AY;+00,1,3|}
{D0130,0480,0100|}
{C|}
2nd label data (underway
{LC;0010,0010,0470,0060,1,2|}
{XB00;0200,0050,0,3,02,0,0050,+0
2nd transmission:
{AY;+00,1,3|}
{D0230,0480,0200|}
{C|}
{LC;0010,0010,0470,0060,1,2|}
2nd label data
{XB00;0200,0050,0,3,02,0,0050,+0000000000,020,1,00|}
{RB00;0000002|}
{XS;I,0001,0000C2011|}
Print result:
The 1st label data is printed after the 1st transmission, and a command error
occurs after the 2nd transmission.
Transmits the 2nd label from the
beginning.
Interrupts communication while the
command is running.