CHAPTER 4 TRANSMISSION SEQUENCE
B-EP
Series
4-25
(5)
When interrupting communication with the PC Save Command separator, and then
retransmitting data from the beginning,
1st transmission:
{XO;25,S0,1|}
{D1430,0480,1400|}
{C|}
{LC;0000,0000,0050,0000,0,1|}
{LC;0000,0001,0050,0001,0,1|}
1st label data
{LC;0000,0002,0050,0002,0,1|}
{LC;0000,0003,0050,0003,0,1|}
{LC;0000,0004,0050,0004,0,1|}
2nd transmission:
{XO;25,S0,1|}
{D1430,0480,1400|}
{C|}
{LC;0000,0000,0050,0000,0,1|}
{LC;0000,0001,0050,0001,0,1|}
{LC;0000,0002,0050,0002,0,1|}
{LC;0000,0003,0050,0003,0,1|} 1st
label data (retransmission)
{LC;0000,0004,0050,0004,0,1|}
{LC;0000,0005,0050,0005,0,1|}
{XS;I,0001,0000C1001|}
{XP|}
{XQ;25,S0,1,L|}
Storage result:
Data is properly stored.
Interrupts communication with the
command separator.
Transmits data from the beginning.