CHAPTER 4 TRANSMISSION SEQUENCE
B-EP
Series
4-33
4.3.3.2 FORM STORE COMMAND
When transmission is cancelled while form storage data is transmitted from the application, the
data may not be properly stored because data subsequently transmitted is stored in the form
unless the Form Store Terminate Command is issued before the transmission is cancelled.
If communication is interrupted while form storage data is transmitted, it is necessary to issue the
Form Store Terminate Command, turn off and on the power of the printer, or reset the printer.
[Command transmission and storage results (Examples)]
(1) When transmitting form storage data as usual,
[1B]XO;01,1[0A][00]
[1B]AY;+00,1[0A][00]
[1B]AX;+000[0A][00]
[1B]D0450,0480,0420[0A][00]
[1B]LC;0050,0030,0250,0030,1,1[0A][00]
[1B]LC;0050,0060,0250,0060,1,2[0A][00]
[1B]LC;0050,0090,0250,0090,1,3[0A][00]
1st label data
[1B]LC;0050,0120,0250,0120,1,4[0A][00]
[1B]LC;0050,0150,0250,0150,1,5[0A][00]
[1B]LC;0050,0180,0250,0180,1,6[0A][00]
[1B]XP[0A][00]
[1B]X[01][21][01][00]
Storage result:
Data is properly stored.