CHAPTER 4 TRANSMISSION SEQUENCE
B-EP
Series
4-59
(4) When interrupting communication while the Page Mode Command is running, issuing the
Cancel Command during retransmission and then retransmitting data from the beginning,
1st transmission:
[ESC]L
DATA001[LF]
DATA002[LF]
DATA003[LF]
1st label data (underway)
DATA004[LF]
DATA005[LF]
2nd transmission:
[CAN]
[ESC]L
DATA001[LF]
DATA002[LF]
DATA003[LF]
1st label data (retransmission)
DATA004[LF]
DATA005[LF]
DATA006[LF]
[FF]
Print result:
Data is properly printed (as shown below).
Issues the Cancel Command and
transmits data from the beginning.
Interrupts communication while
the command is running.
DATA001[LF]
DATA002[LF]
DATA003[LF]
DATA004[LF]
DATA005[LF]
DATA006[LF]