CHAPTER 5 TPCL MODE (INTERFACE COMMANDS)
B-EP
Series
5-15
g:
Reserved area (Omissible)
hhh:
Reserved area (Omissible)
Explanation
(1)
When the parameter “a” is set to any value other than “+” or “-,“ a command error occurs.
(2) If any value out of the above range is specified for the fine adjustment value for print
position, a command error occurs.
(3) When any value above + 10.5 mm (- 1 mm distance between the head and sensor) is
specified for the fine adjustment value for print position, it should be changed to + 10.5
mm before printing.
(4)
The reserved area is not checked.
(5) The fine adjustment value for strip position is valid only when “the compatible mode for
the B-SP series” is turned off (disabled) in the SYSTEM mode. When the parameter “a”
is set to any value other than “+” or “-,“ a command error occurs. When the parameter
“a” is set to any value other than “+” or “-,“ a command error occurs. When the
“compatible mode for the B-SP series” is turned on (enabled), the value is ignored.
[Print position (feed value) fine adjustment]
(To finely adjust the print position so that it shifts backward or forward)
Paper feed direction
± 0.0 mm
- 3.0 mm
One label
+ 3.0 mm
Print start position
Print start position
Print start position
One label
One label