CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
B-EP
Series
5-42
(10)
Increment/decrement
Printing is performed while the data is incremented or decremented every time a label is
issued. Where the data row exceeds the maximum number of digits (40), the data row
will not be drawn.
When the font type is U, V, r, s, w, a (for JA type only), 41, 42, 43 or 51, increment/
decrement cannot be designated.
(Even if it is designated, it is ignored.)
Initial
value 0000 0000 0000 0000 999999
INC/DEC +10 +10 +10 +10
+1
Zero suppression
Not
designated
5 3 0 3
1st label
0000
0000
000
0000
999999
2nd label
0010
0010
010
0010
000
3rd label
0020
0020
020
0020
001
4th label
0030
0030
030
0030
002
5th label
0040
0040
040
0040
003
Letters and numerals for increment/decrement
For the data string, up to 40 digits (including letters, numerals, and symbols) are
possible. Only the numerals are selected and calculated for
incrementing/decrementing, and then are returned to the previous position to draw the
data.
Example of increment/decrement calculation
Initial value
00000
A0A0A
7A8/9
A2A0A
INC/DEC +1 +1 +3 -3
1st label
00000
A0A0A
7A8/9
A2A0A
2nd label
00001
A0A1A
7A9/2
A1A7A
3rd label
00002
A0A2A
7A9/5
A1A4A
4th label
00003
A0A3A
7A9/8
A1A1A
5th label
00004
A0A4A
8A0/1
A0A8A
(11)
Zero
suppression
No. of digits after zero
suppression
0 1 2 2 3 4 5
Data 0000
0000
0000
0A12
0123
0123
0123
Print 0000
0
00
A12
123
0123
0123
Zero(s) in a data row is replaced with a space(s) from the upper digits, according to the
designated number of digits. However, if the number of digits after zero suppression is
greater than the data row, the data row will be drawn without performing zero suppression.
Where the data row exceeds the maximum number of digits (40), the data row will not be
drawn.
When the font type is U, V, r, s w, a (for JA type only), 41, 42, 43 or 51, zero suppression is
not designated.