CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
B-EP
Series
5-51
j:
Character
attribution
B: Black
character
W (aabb): Reverse character
aa: No. of dots from the character string to the end of the black
background in the horizontal direction
bb: No. of dots from the character string to the end of the black
background in the vertical direction
aa:
01 to 99 (in units of dots)
bb:
01 to 99 (in units of dots)
F (aabb): Boxed character
aa: No. of dots from the character string to the box in the horizontal
direction
bb: No. of dots from the character string to the box in the vertical
direction
aa:
01 to 99 (in units of dots)
bb:
01 to 99 (in units of dots)
* Reserved in the case of the compatible mode for the B-SP series
(If specified, it is processed as “B.”)
C (aa):
Strike-through character
aa: No. of dots from the character string to the end of a strike-through in
the horizontal direction
aa: 01 to 99 (in units of dots)
* Reserved in the case of the compatible mode for the B-SP series
(If specified, it is processed as “B.”)
* Parenthesized descriptions are omissible. (If omitted, it is character size (the
character width or height, whichever is greater) ÷ 8 dots.)
Mk:
Type of the check digit to be attached
(Omissible. If omitted, no check digit is drawn.)
k:
Type of check digit
0: Modulus 10 (Draws data and check digit.)
1: Modulus 43 (Draws data and check digit.)
2: DBP Modulus 10 (Draws check digit only.)
* Reserved in the case of the compatible mode for the B-SP series
lmmmmmmmmmm: Increment and decrement
(Omissible. If omitted, increment/decrement is not performed.)
l: Designates whether to increment or decrement.
+: Increment
-: Decrement
mmmmmmmmmm:
Skip
value
0000000000 to 9999999999
Znn:
Zero suppress (Omissible. If omitted, zero suppression is not performed.)
pp:
No. of digits after zero suppression
00 to 20