CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
B-EP
Series
5-52
Po:
Alignment (Omissible. If omitted, the alignment is set to the left.)
o: Designates the character position.
1:
Left
2:
Center
3:
Right
4aaaa: Justification
aaaa:
Character string in the X direction
0050 to 1040 (in 0.1 mm units)
* 4 is reserved in the case of the compatible mode for the B-SP series.
(If specified, it is processed as “1.”)
Ipp:
Italic (Omissible. If omitted, the italic is not applied. Only TEC FONT1 is
supported)
pp: Angle of the italic
00 to 45 (in units of degrees)
Qoooo: Character string width (Omissible. If omitted, it is 0000.)
0000 to 1600 (in 0.1 mm units)
Rpp:
No. of character string digits
(Omissible. If omitted, it is 00.)
00 to 99
qqq ------ qqq:
Data string to be printed (Omissible)
Max. 255 digits
rr
1
, rr
2
, rr
3
------ , rr
20
:
Link field No. (Omissible)
01 to 99 (1 to 99 can also be used.)
Up to 20 fields can be designated using commas.