CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
B-EP
Series
5-83
5.6.5
BARCODE FORMAT COMMAND
[ESC] XB
~
In the case of MSI, Interleaved 2 of 5, CODE39, NW7, Industrial 2 of 5, MATRIX 2 of 5 for NEC
Format
c
[ESC] XBaa; bbbb, cccc, d, e, ff, gg, hh, ii, jj, k, llll (, mnnnnnnnnnn, p, qq) (, r)
(= sss ------ sss) [LF] [NUL]
d
[ESC] XBaa; bbbb, cccc, d, e, ff, gg, hh, ii, jj, k, llll (, mnnnnnnnnnn, p, qq) (, r)
(; tt
1
, tt
2
, tt
3
, ------, tt
20
) [LF] [NUL]
Term aa:
Barcode
number
00 to 31
bbbb:
X-coordinate of the print origin of barcode
Fixed at 4 digits (in 0.1 mm units)
cccc:
Y-coordinate of the print origin of barcode
4 or 5 digits (in 0.1 mm units)
d:
Type of barcode
1: MSI
2: Interleaved 2 of 5 (ITF)
3: CODE39 (standard)
4: NW7
B: CODE39 (full ASCII)
O: Industrial 2 of 5
a: MATRIX 2 of 5 for NEC
e:
Type of check digit
1: Without attaching check digit
2: Check digit check
CODE39
Modulus
43
MSI
IBM modulus 10
ITF
Modulus
10
Industrial 2 of 5
Modulus check character
MATRIX 2 of 5 for NEC
Modulus check character
3: Check digit automatic attachment (1)
CODE39
Modulus
43
MSI
IBM modulus 10
ITF
Modulus
10
Industrial 2 of 5
Modulus check character
MATRIX 2 of 5 for NEC
Modulus check character
4: Check digit automatic attachment (2)
MSI
IBM modulus 10 + IBM modulus 10
ITF
DBP Modulus 10
5: Check digit automatic attachment (3)
MSI
IBM modulus 11 + IBM modulus 10
ff:
Narrow bar width
01 to 99 (in units of dots)
gg:
Narrow space width
01 to 99 (in units of dots)
* In the case of industrial 2 of 5, designate an element-to-element space.