CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
B-EP
Series
5-104
h:
Rotational angle of two-dimensional code
0: 0°
1: 90°
2: 180°
3: 270°
Ciiijjj:
No. of cells
(Omissible. If omitted, it is automatically set.)
iii: No. of cells in the X direction
000 to 144
jjj: No. of cells in the Y direction
000 to 144
* Cell setting varies according to the ECC type.
ECC000 to ECC140
ECC200
No. of cells to be
designated
Odd numbers only
Even numbers only
Min./Max. No. of cells
9 × 9 to 49 × 49
10 × 10 to 144 × 144
Rectangular code
None
18 × 8
32 × 8
26 × 12
36 × 12
36 × 16
48 × 16
* When this parameter is omitted, the number of cells is automatically
set. Also, when any data other than the above values are
designated for the number of cells in the X and Y directions, the
number of cells is automatically set.
Jkkllmmmnnn:
Connection
setting
(Omissible. If omitted, connection is not made.)
kk:
Code number
01 to 16
ll:
No. of divided codes
02 to 16
mmm: ID number 1
001 to 254
nnn:
ID number 2
001 to 254
ooo ------ ooo:
Data string to be printed (Omissible)
Max. 2000 digits
pp
1
, pp
2
, pp
3
, ------, pp
20
:
Link field No. (Omissible)
01 to 99 (1 to 99 can also be used.)
Up to 20 fields can be designated using commas.
* The maximum of 2000 digits of data string to be printed and the maximum of 99 dots of the 1-cell
width are acceptable. (The maximum number of digits of the data string to be printed differs
depending on the ECC level and the contents of data.) However, note the following limits:
• The maximum of 2000-digit data string to be printed are acceptable. However, it cannot actually be
printed, since it cannot be contained within the 2-inch head width.
• If the print ratio of one line (the print head width) is high, printing may become poor, or the printer
may be reset. Be careful about the print ratio.
• When a large value is set for the 1-cell width, decrease the number of digits of data to contain the
data within the head width.