CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
B-EP
Series
5-168
Notes
(1) If the label size, type of sensor, feed amount fine adjustment or strip position fine
adjustment is changed, the Feed Command must be sent to adjust the print start position
prior to printing by feeding one label.
(2)
The parameter of the Feed Command is stored in memory (retained even if the power is
turned off).
(3)
When “status response is returned.” has been selected using the Issue Command, a
status response is returned after the end of feed or when an error occurs.
(4)
Refer to ISSUE COMMAND for the operation to stop the label at the home position.
Examples
[ESC] D0762, 0820, 0732 [LF] [NUL]
[ESC] AX; +010, +000, +10 [LF] [NUL]
[ESC] T11C40 [LF] [NUL]
[ESC] C [LF] [NUL]
[ESC] PC001; 0150, 0410, 1, 1, A, 00, B [LF] [NUL]
[ESC] RC001; Sample [LF] [NUL]
[ESC] XS; I, 0004, 0011C43001 [LF] [NUL]
76.2 mm
S a m p l e
41.0
mm
73.2
mm
15.0 mm
82.0 mm
Paper feed direction