CHAPTER 6 LABEL MODE (INTERFACE COMMANDS)
B-EP
Series
6-12
Explanation
(1) The print start position is adjusted to stop backward or forward from the standard
print start position.
(2) When the back feed amount fine adjustment is enabled by this command while the
command is being stored in a form, the print start position moves backward by
2mm from the standard position, which enlarges the effective print area.
(3) If this command is stored in a form, the print position is automatically adjusted
when the form is invoked.
(4) When the back feed amount fine adjustment is enabled by this command while the
command is being stored in a form, or when the command is sent without being
stored in a form, printing starts at 5 mm from the leading edge of the label.
(5) When the power is turned on again, the backed up fine adjustment value is set.
(6) When the print position is changed, or when the gap between the labels is not 3
mm, the Position Fine Adjust Command should be used as required. (When the
gap between the labels is 3 mm, the standard print start position is 5 mm from the
leading edge of the label.)
(7) When the compatible mode for the B-SP series is off, and the reserved area (,eff)
is set to +20, printing starts at 3 mm from the leading edge of the label. When this
parameter is omitted, printing starts at 5 mm from the leading edge of the label.
Note that when the parameter is set to any value other than +20, a command error
occurs.
(8) When the compatible mode for the B-SP series is on, and the omissible
parameters (,cddd and ,eff) are set to +000 and +20, respectively, printing starts at
3 mm from the leading edge of the label. When the parameters are omitted,
printing starts at 5 mm from the leading edge of the label. Note that when the
parameters are set to any value other than +000 and +20, respectively, a
command error occurs.
(9) When the fine adjustment for print position in + (backward) direction is set to any
value exc10.5 mm (distance between the print head and the sensor minus
1 mm), the fine adjustment value is corrected to +10.5 mm before printing.
(10) The fine adjustment value for strip position is valid only when “the compatible mode
for the B-SP series” is turned off (disabled) in the SYSTEM mode. When the