CHAPTER 6 LABEL MODE (INTERFACE COMMANDS)
B-EP
Series
6-32
g
When one field width
≥
specified character string width
(Space between characters < 0, Specified character string digits = 5)
Print image when the parameter setting is omitted.
A=1 field width – Specified character string width=185 dots – 120 dots=65 dots
B=A/Data length=65 dots/4=17 dots (rounded up)
One character width=1 character width – B=50 dots – 17 dots=33 dots
Print image when the parameter setting is specified.
* When the number of print data is 5 digits or more, the condition of
ineffectiveness (3) is satisfied. In this case, the characters are printed in
normal width.
Example
[ESC] XO; 01, 1 [LF] [NUL]
[ESC] D0430, 0480, 0400 [LF] [NUL]
[ESC] PV00; 0030, 0120, 0050, 0050, A, 00, B, 00, 1, 0, P0 [LF] [NUL]
[ESC] XP [LF] [NUL]
Data print command (not for IrDA:TEC Protocol)
[ESC] X [01H] [01H] [01H] SAMPLE [LF]
Sample
Origin of
coordinates
(0, 0)
(3 mm, 12 mm)
Effective print width
Effective
print length
Outline font character
string No. 00
TEC Font 1 (80×80 mm)
Backing paper
Label
1 field width (185 dots)
A
Specified character string width (117 dots)
A
B
C
D
Specified character string width (120 dots)
One character width (50dots)
Space between characters (-15 dots)
A B C D
One character width (33 dots)
Space between characters (-5 dots)