• Battery status .. The battery charge status is indicated in 5 levels.
(B-EP2DL)
01H: 7.2 V or less (Print failure)
02H: 7.3 V to 7.4 V (remaining No. of printable labels: Approx. 1 to 30)
03H: 7.5 V to 7.7 V (remaining No. of printable labels: Approx. 30 to 150)
04H: 7.8 V to 7.9 V (remaining No. of printable labels: Approx. 150 to 300)
05H: 8.0 V to 8.4 V (remaining No. of printable labels: Approx. 300 or more)
(B-EP4DL)
01H: 14.0 V or less
(Print failure)
02H: 14.1 V to 14.6 V (remaining No. of printable labels: Approx. 1 to 30)
03H: 14.7 V to 15.2 V (remaining No. of printable labels: Approx. 30 to 150)
04H: 15.3 V to 15.9 V (remaining No. of printable labels: Approx. 150 to 300)
05H: 16.0 V to 16.8 V (remaining No. of printable labels: Approx. 300 or more)
*
The remaining number of printable labels may vary according to the contents to be