- 177 -
6.4 COMMANDS FOR SYSTEM ADMINISTRATOR
6.4.1 PARAMETER SET COMMAND
[ESC] Z2; 1
Function
Sets each parameter on the printer.
Format
[ESC] Z2; 1, abcdefghijklmnopqqrst(uvw) [LF] [NUL]
Term
a:
Character code selection
0: PC-850
1: PC-852
2: PC-857
3: PC-8
4: PC-851
5: PC-855
6: PC-1250
7: PC-1251
8: PC-1252
9: PC-1253
A: PC-1254
B: PC-1257
C: LATIN9
D: Arabic
b:
Font “0” selection
0: 0 (without slash)
1: 0 (with slash)
c:
RS-232C communication speed
0: 2400 bps
1: 4800 bps
2: 9600 bps
3: 19200 bps
4: 38400 bps
5: 57600 bps
6: 115200 bps
d:
RS-232C data length
0: 7 bits
1: 8 bits
e:
Stop bit length
0: 1 bit
1: 2 bits
f:
RS-232C parity check (Not initialized by parameter clearance by key operation)
0: NONE (QM)
1: EVEN (JA/CSG)
2: ODD
Summary of Contents for B-EV4 Series