2. PRINTER SETUP
ENGLISH VERSION EO1-33089
2.9 Position and Print Tone Fine Adjustment
E2-66
2.9.1 Fine Adjustment (Cont.)
(8) RBN ADJ.<BK>
When the ribbon is slack or wrinkled and printing is affected, fine
adjust the ribbon motor torque.
(9) THRESHOLD <REFL.>
When you perform a threshold setting for the reflective sensor and found
the threshold needs to be adjusted, set a fine adjustment value.
This menu is accessible directly from the Threshold Setting Mode so that
the threshold can be manually set right away.
Manually set threshold = Peak voltage – The value set here
For details, refer to
Section 2.10
.
(10) THRESHOLD <TRANS.>
When you perform a threshold setting for the Transmissive sensor and
found the threshold needs to be adjusted, set a fine adjustment value.
This menu is accessible directly from the Threshold Setting Mode so that
the threshold can be manually set right away. .
Manually set threshold = Peak voltage – The value set here
For details, refer to
Section 2.10
.
+10
-15
+9
-14
High
Low
Motor torque
NOTE:
When “0.0 V” is se for this
parameter, it is automatically
corrected to 1.4V (default)
after the power is turned OFF
then ON.
NOTE:
When “0.0 V” is se for this
parameter, it is automatically
corrected to 1.0V (default)
after the power is turned OFF
then ON.
4.0V
0.0V
3.9V
0.1V
4.0V
0.0V
3.9V
0.1V