110
9.8 RAM CLEAR
Contents of RAM CLEAR menu
Menu item
<8>RAM CLEAR
NO RAM CLEAR
MAINTE.CNT CLEAR
PARAMETER CLEAR
9.8.1 NO RAM CLEAR
This option is provided for users who access this menu by mistake, and intended to exit from the RAM clear
menu without performing any RAM clear.
9.8.2 MAINTE.CNT CLEAR
The following maintenance counter data is cleared.
・
ALL COUNTER
FEED
CUT
OTHER
Notes: 1. Maintenance counter data to be cleared and the initial values after maintenance counter clear
Maintenance counter item
Initial value
Parameter and cleared items
ALL
COUNTER
FEED
CUT
OTHER
Label distance covered
0 km
Cleared
Cleared
Print distance
0 km
Cleared
Cleared
Cut count
0
Cleared
Cleared
Head up/down count
0
Cleared
Cleared
Ribbon motor drive time
0 hours
Cleared
Cleared
Head-up solenoid driver time
0 hours
Cleared
Cleared
RS-232C hardware error count
0
Cleared
Cleared
System error count
0
Cleared
Cleared
Momentary power interruption count
0
Cleared
Cleared
<Reference: Maintenance counter printout>
<< COUNTER >>
TOTAL FEED 4.8km
[QM]
FEED
0.0km ···
Label distance covered
FEED1
4.8km
FEED2
0.0km
FEED3
0.0km
FEED4
0.0km
0.0km ···
②
Print distance
PRINT1
4.5km
PRINT2
0.0km
PRINT3
0.0km
PRINT4
0.0km
CUT
0 ·········
③
Cut count
HEAD U/D
0 ·········
④
Head up/down count
RIBBON
0h ·······
⑤
Ribbon motor drive time
SOLENOID 0h ·······
⑥
Head-up solenoid driver time
232C ERR
0 ·········
⑦
RS-232C hardware error count
SYSTEM ERR 0 ·········
⑧
System error count
POWER FAIL 0 ·········
⑨
Momentary power interruption count