41
7.2 VALUE SETTING SCREEN
The value setting screen is used for setting a value by increasing or decreasing it.
It is comprised of the following parts.
Display example
FEED ADJ.
+0.0
mm
(-50.0 - +50.0)mm
Notes:
1. The currently programmable item is highlighted.
2. The display of the symbols like
“+” and “-“, and the unit of measure like “mm” and “step” differs depending on
the item to be set.
Display
Setting screen with one field
FEED ADJ.
+0.0
mm
(-50.0 - +50.0)mm
Setting screen with multiple fields (placed
horizontally)
IP ADDRESS
192
.168 .010 .002
Setting screen with multiple fields (placed
vertically)
READ RETRY
5
times
4.0 sec
( 0.0 - 9.9 )sec
( 0 - 255 )times
Key function (Setting screen with one field)
Key
Substitute Key
Function
[MODE]
None
Returns to the top menu without saving changes.
[CANCEL]
[FEED] + [RESTART]
Returns to the upper-level menu without saving changes.
[ENTER]
[PAUSE]
Saves the changes and returns to the upper-level menu.
[UP]
[RESTART]
Increases the setting value by specified step. When the setting
value reaches the maximum, it returns to the minimum value
and increases.
[DOWN]
[FEED]
Decreases the setting value by specified step. When the
setting value reaches the minimum, it returns to the maximum
value and decreases.
[LEFT]
None
No function
[RIGHT]
None
No function
Setting value
Setting range
Title