-51-
(6) Sensor check
SENSOR1 0 0 0 0 0 0 0 0 , 0 0 0 0 0 0 1 0
Blank (Fixed to 0)
Cover open sensor
1: The cover is closed.
(Printing is not performed when the cover is open.)
Blank (Fixed to 0)
Blank (Fixed to 0)
SENSOR2 [H]+20
゚
C [A]+22
゚
C
Ambient thermistor status
(-15 °C to 99°C, --°C: if the temperature cannot be detected)
Thermal head thermistor status (-15 °C to +70 °C)
[R]4.2V [T]2.5V
Transmissive sensor status (0.0V to 5.0V)
Reflective sensor status (0.0V to 5.0V)
PE LV. [R]1.8V [T]2.5V
Transmissive sensor for no paper level (0.0V to 5.0 V)
Reflective sensor for no paper level (0.0V to 5.0 V)
No paper level
M THRE. [R]1.8V [T]2.5V
Transmissive sensor for no paper level (0.0V to 5.0 V)
Reflective sensor for no paper level (0.0V to 5.0 V)
Threshold value