-84-
7.5.6
Strip Position Fine AdjustmentPeel Adjust
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+3.0
-2.0
0.1
Decimal
Exist
1
1
None
mm
Default value: 0.0mm
Regardless of gap length, the stop position in strip issue mode is designed
in a manner so that printing stops when the distance from the top edge of
the strip shaft to the trailing edge of the label is 1 mm, if print position fine
adjustment value is not set.
If the above-mentioned stop position is not proper, the stop position should
be adjusted using the stop position fine adjust function for the strip issue.
<Supplemental Explanations>
・
The printer is controlled by the total amount determined by this command and the Position Fine
Adjustment command sent from the PC (strip position fine adjustment value). However, the
maximum value is
–2.0 mm to +3.0 mm.
Support mode (o
:
valid
、
x
:
invalid
)
TPCL, TPCL1,
LABEL
C Mode
ESC/POS
RECEIPT,RECEIP
T1
Z Mode
S Mode
o
o
o
o
o
+0.0 mm
+3.0 mm
-2.0 mm
Strip stop position (top edge of strip shaft)
Paper feed direction
Strip stop position (top edge of strip shaft)
Strip stop position (top edge of strip shaft)
3 mm ~ 7 mm
1 mm