APPENDIX 1 MESSAGES AND LEDS
ENGLISH VERSION EO1-33059
APPENDIX 1 MESSAGES AND LEDS
EA1- 2
LED Indication
No.
LCD Message
POWER ONLINE ERROR
Printer Status
Restoration by
RESTART key
Yes/No
Acceptance of
Status Request
Reset Command
Yes/No
22 SYSTEM ERROR
z
When the following abnormal
operations are performed, a system
error occurs:
(a) Command fetch from an odd
address
(b) Access to word data at an odd
address
(c) Access to long-word data at an odd
address
(d) Access to the area of 80000000H to
FFFFFFFFH in the logic space in
user mode.
(e) An undefined instruction in an area
other than a delay slot was
decoded.
(f) An undefined instruction in a delay
slot was decoded.
(g) An instruction to rewrite a delay
slot was decoded.
No No
23
100BASE LAN
INITIALIZING…
z
z
100 Base LAN Board is being
initialized.
----- -----
24
RFID WRITE ERROR
z
The printer did not succeed in writing
data onto an RFID tag after having
retried for a specified times
Yes Yes
25
RFID ERROR
z
The printer cannot communicate with
the RFID module
Yes Yes
NOTE: When an error message listed above appears on the LCD message display, please refer to Section 5
TROUBLESHOOTING for solution.
Summary of Contents for B-SX5T Series
Page 3: ...TEC Thermal Printer B SX5T SERIES Owner s Manual ...
Page 120: ...M EO1 33059 ...